B680H 35 732719 - Rev.E
Translation of the original instructions
ENGLISH
Expert Function Setting
19
If you enable this function, during closing, LOOP2 stops the movement and allows it to resume
once released, otherwise it reverses immediately during opening.
Y = close when released
no = reverse immediately
20
If you enable this function, LOOP2 closes the automation when it is released (also see
parameter 21).
Y = close if LOOP2 is free
no = disabled
21
If you enable this function, and if parameter 20 = Y, the unit waits for the opening cycle
to end before carrying out the closing command issued by LOOP2.
Y = close at the end of opening
no = disabled
22
If you enable this function: if there is a power failure, when the power comes back on, if an
OPEN command is not active, the automation closes immediately.
Y = enabled
no = disabled
23
LOOP1 commands opening and, once opened, closes if released (useful if a vehicle reverses
with consecutive loops). If disabled when LOOP1 is released, closing is not carried out.
Y = close if LOOP1 is free
no = disabled
24
If you activate this function, an opening or closing command is carried out only when the
safeties are released.
Y = enabled
no = disabled
25
A.D.M.A.P. function
If you enable this function, the safety devices operate according to French standards.
Y = enabled
no = disabled
26
If you enable this function, during closing the SAFETIES IN CLOSING stop and reverse the
movement when released, otherwise they reverse immediately.
Y = stop and reverse when re-
leased.
no = reverse immediately.
27
DO NOT MODIFY
no
28
DO NOT MODIFY
no
29
DO NOT MODIFY
no
30
If you enable this function, LOOP1 commands have priority over LOOP2 commands.
Y = enabled
no = disabled
A0
HOLD CLOSE / HOLD OPEN function
If you enable this function, the automation will check the position of the beam at predeter-
mined times (see parameter A1). If the beam is not completely closed or completely open
(depending on the logic of the board), the automation will carry out a closing or opening
movement for a maximum of 3 seconds to bring the beam back to the correct position. If
after 3 seconds, the beam does go back to the completely closed / open position (for example
because the beam has been released) the function will be disabled until a subsequent OPEN
command is given.
Y
A1
HOLD CLOSE / HOLD OPEN function activation time
This parameter is the time interval between two activations of the HOLD OPEN / HOLD CLOSE
function, expressed in minutes. (from 00 to 99)
01
r1
Frequency reading LOOP1
This option in the menu allows you to check the actual oscillation frequency reading of the loop connected to input LOOP1. It
is read as follows:
- First digit: tens (kHz)
- Second digit: units (kHz)
- Decimal point: Hundreds (kHz)
For example a reading indicated as 05. refers to a reading of 105 kHz
Read only parameter