B680H 39 732719 - Rev.E
Translation of the original instructions
ENGLISH
5.2 PARAMETER CF
The correct default has to be set in the first basic
programming function according to the length of the
beam and the number of accessories installed.
7 Default parameter
cF - S beam
L 2 m 2.5 m 3 m 3.5 m 4 m 4 m (*) 4.5 m 5 m 5 m (*)
Beam 1 1 2 2 2 3 3 3 3
Beam and lights 1 1 2 2 2 3 3 3
Beam, lights and
hedge
1 1 2 3 3 3 3
Beam, lights, foot and
hedge
1 2 2 3 3 3 3
Beam, lights and foot 1 2 2 3 3 3 3
Beam and foot 1 1 2 3 3 3 3
Beam and hedge 1 1 2 2 3 3 3
Beam, hedge and foot 1 2 2 3 3 3 3
Jointed beam 1 2 1 3 3
(*) with joint
8 Default parameter
cF - L beam
L 5 m (**) 5 m 5.5 m 6 m 6.5 m 7 m 7.5 m 8 m
Beam 4 4 5 5 5 5 5 6
Beam and lights 4 4 5 5 5 5 6 6
Beam, lights and
hedge
4 5 5 6 6 6 6
Beam, lights,
foot and hedge
5 5 5 5 6 6
Beam, lights and
foot
4 5 5 5 5 6 6 6
Beam and foot 4 5 5 5 5 5 6 6
Beam and hedge 4 5 5 5 5 6 6
Beam, hedge
and foot
5 5 5 5 5 6
(**) without joint