B680H 36 732719 - Rev.E
Translation of the original instructions
ENGLISH
Expert Function Setting
r2
Frequency reading LOOP2
This option in the menu allows you to check the actual oscillation frequency reading of the loop connected to input LOOP2 (see
parameter r1 regarding how to read the value shown)
Read only parameter
F1
Frequency selection LOOP1
This parameter allows you to set a specific oscillation frequency for the loop connected to
the input LOOP1, or leave it to the system to select the most suitable setting from the 4
levels available.
A Automatic selection
1-2-3-4 Frequency 1-2-3-4
Note: The system is recalibrated when you exit from the ADVANCED programming menu
after having changed the loop operating frequency settings. This allows you to obtain an
updated frequency reading when you go back to the menu to view the values of parameters
r1 or r2
To
F2
Frequency selection LOOP2
This parameter allows you to set a specific oscillation frequency for the loop connected to
the input LOOP2, or leave it to the system to select the most suitable setting from the 4
levels available.
A Automatic selection
1-2-3-4 Frequency 1-2-3-4
Note: The system is recalibrated when you exit from the ADVANCED programming menu
after having changed the loop operating frequency settings. This allows you to obtain an
updated frequency reading when you go back to the menu to view the values of parameters
r1 or r2
To
h1
Hold time LOOP1
Used for setting the presence time on LOOP1. When this time has elapsed, the board
calibrates itself and indicates “loop free” (led DL3 off). An automatic reset is carried out
when the board is switched on.
Y 5 minutes
no infinite
no
h2
Hold time LOOP2
Used for setting the presence time on LOOP2. When this time has elapsed, the board
calibrates itself and indicates “loop free” (led DL4 off). An automatic reset is carried out
when the board is switched on.
Y 5 minutes
no infinite
no
H1
Articulated lorry function LOOP1
This function allows you increase the level of sensitivity at the time of detection in order
to allow correct detection even in the case of very high vehicles or during the transit of a
tractor unit and trailer.
Y enabled
no disabled
Y
H2
Articulated lorry function LOOP2
This function allows you increase the level of sensitivity at the time of detection in order
to allow correct detection even in the case of very high vehicles or during the transit of a
tractor unit and trailer.
Y enabled
no disabled
Y