Installation manual
CNC 8055
CNC 8055i
MACHINE PARAMETERS
6.
SOFT: V02.2X
·181·
General machine parameters
HANDWHE1 (P112) / HANDWHE2 (P113) / HANDWHE3 (P114) /HANDWHE4 (P115).
To define the type of handwheel and its associated axis, use the following general parameters:
HANDWHE1 (P112) for the first handwheel.
HANDWHE2 (P113) for the second handwheel.
HANDWHE3 (P114) for the third handwheel.
HANDWHE4 (P115) for the fourth handwheel.
The values to be assigned to these parameters are:
A general handwheel (11 or 12) and up to 3 handwheels associated with the axes can be used
simultaneously. There cannot be 2 general handwheels.
STOPTAP (P116)
Indicates whether the general inputs /STOP (M5001), /FEEDHOL (M5002) and /XFERINH (M5003)
are enabled (P116=YES) or not (P116=NO) while executing function G84, regular tapping or rigid
tapping.
INSFEED (P117)
Sets the tool inspection feedrate.
When accessing tool inspection, the CNC assumes this feedrate as the new one, and it resumes
the execution of the program at the previous feedrate (the one used in the program or set via MDI
while in tool inspection) when tool inspection is over.
If set to "0" (by default), tool inspection will be carried out at the feedrate currently used for machining.
DISTYPE (P118)
Only to be used by Fagor Automation technical personnel.
PROBERR (P119)
Indicates whether the CNC issues an error message when the axes reach the programmed position
without having received the probe signal while executing function G75 or G76.
Value Meaning Value Meaning
11 Handwheel. 12 Handwheel with axis selector button
21 Handwheel associated with X. 22 Handwheel associated with Y.
23 Handwheel associated with Z. 24 Handwheel associated with U.
25 Handwheel associated with V. 26 Handwheel associated with W.
27 Handwheel associated with A. 28 Handwheel associated with B.
29 Handwheel associated with C.
Possible values
Between 0.0001 and 199999.9999 degrees/min or mm/min.
Between 0.00001 and 7874.01574 inches/min.
Default value: EZ
Value Meaning
YES It issues the error message.
EZ It does NOT issue the error message.
Default value: EZ