Installation manual
CNC 8055
CNC 8055i
MACHINE PARAMETERS
6.
SOFT: V02.2X
·259·
Spindle parameters
This parameter is only taken into account for the "anti-resonance (notch)" filter type.
It is calculated with the following formula.
Points f1 and f2 correspond to the cutoff frequency or frequency at which its amplitude drops 3 dB
or reaches 70% of the nominal amplitude.
SHARE (P71)
percentage of signal going through the filter. This value must be equivalent to the percentage
overshooting of the resonance because it has to make up for it.
This parameter is only taken into account for the "anti-resonance (notch)" filter type.
Possible values
between 0 and 100.0
Default value: 1
ff
1
2
FREQUEN
A
Ao
0,707·Ao (-3dB)
NORBWID
FREQUEN
f
2
f
1
–
-----------------------------
=
Possible values
between 0 and 100
Default value: 100
Calculation example for a particular response of the machine.