Installation manual
CNC 8060
CNC 8065
LOGIC CNC INPUTS AND OUTPUTS.
6.
(REF: 1402)
·297·
General consulting signals.
Include this mark in the PLC routine to restrict the CNC operation in case of over-
temperature.
MLINKRDY
In Mechatrolink configuration, this mark indicates the bus status. The CNC activates this
mark to indicate that the Mechatrolink bus has been properly initialized.
All status consultations of the servos and inverters and the read/write (CNCRD/CNCWR)
operations of their variables must be conditioned by this mark. The status of the servos and
inverters may be consulted using the following variables.
If the PLC activates this mark, there is an over-temperature risk and the integrity of the unit is at risk.
Turn the unit off to avoid possible damage.
V.A.MSTATUS.xn V.A.MSUBSTAT.xn V.A.MALARM.xn V.A.MIOMON.xn