·208·
Installation manual
CNC 8060
CNC 8065
2.
MACHINE PARAMETERS.
(REF: 1402)
Machine parameters for HMI (Interface).
2.11 Machine parameters for HMI (Interface).
These parameters are used to define the communication environment (interface) between
the operator and the CNC. To validate the changes made to these parameters, the CNC must
be reset.
INTERFACE SETTING.
WINDOW
Dimensions of the main window.
This parameter shows the data to configure the main window. The table has the following
machine parameters.
POSX
X coordinate of the top left corner.
Default value: 0.
Parameter included in the WINDOW table.
This parameter cannot be modified.
POSY
Y coordinate of the top left corner.
Default value: 0.
Parameter included in the WINDOW table.
This parameter cannot be modified.
WIDTH
Width of the window.
Possible values: From 800 to 1024.
Default value: 800.
Parameter included in the WINDOW table.
The size of the window is given in pixels. We recommend no to change this values at the CNC.
HEIGHT
Height of the window.
Possible values: From 600 to 768.
Default value: 600.
Parameter included in the WINDOW table.
The size of the window is given in pixels. We recommend no to change this values at the CNC.
HMITYPE
Interface type of the CNC.
Possible values: Standard / Classic / Advanced.
Default value: Standard
WINDOW
POSX X coordinate of the top left corner.
POSY Y coordinate of the top left corner.
WIDTH Width of the window.