Installation manual
CNC 8060
CNC 8065
CONCEPTS.
9.
(REF: 1402)
·459·
Analog axes.
Feedback input in CANfagor remote modules.
A counter module is used as feedback input in the remote modules. Parameter COUNTERID
indicates the number of the feedback input to be used.
The counter modules are numbered following the logic order of the remote groups (rotary
switch of the power supply). If there are several Counter modules in each group, the order
is from top to bottom and from left to right. The counters of the first module will be 1 through
4, those of the second module 5 through 8 and so on.
Feedback input in Sercos drives.
In this case, the second feedback input of the drive will always be used. Parameter
COUNTERID indicates the logic address of the drive (from 1 to 32). The "address" rotary
selector switch sets the logic address.
Local feedback input.
The central unit has two feedback inputs. Parameter COUNTERID indicates the feedback
input being used.
Parameter. Value.
COUNTERTYPE Remote.
COUNTERID Number of the feedback input.
Parameter. Value.
COUNTERTYPE Drive.
COUNTERID Number of the feedback input.
Parameter. Value.
COUNTERTYPE Local.
COUNTERID Number of the feedback input.