10.
CNC VARIABLES.
(REF: 1402)
Variables related to the machine configuration.
CHANGE THE SIMULATION SPEED FROM THE PLC.
(V.)PLC.SIMUSPEED
Variable that can be read and written from the PLC and read from the program and from the interface.
The variable returns the execution value; reading it interrupts block preparation.
Report variable (to be used from the scripts).
Percentage of simulation speed (between 0% and 100%).
Currently, the simulation displays a horizontal bar on the screen to change the simulation
speed. This variable may be used to change its value via PLC. In some cases, the OEM can
transfer via PLC the feedrate override value to this variable to control the simulation speed.
V.PLC.SIMUSPEED
The execution and simulation channels can work simultaneously in which case, the feedrate override
switch will affect both. It is up to the OEM to use this variable in the right contexts so it only affects one
of the channels.