3-48
Frequently Used Functions
Setup Flow
For the Edge height setting, configure the basic settings with “[S7] - [D2] Threshold mode”, and then execute
the teach function.
Then, configure the setting parameters related to Edge height as necessary.
Settings
Basic settings Threshold mode
Edge direction [S7] - [D2] (page 4-16)
Edge offset
Teach Teach function
execution
Operation Procedure 2 (Teach Function)” (page 3-55)
Setting
confirmation
Edge peak [S9] - [IB] (page 3-53)
Changing
settings
Edge offset
*1
[S7] - [D9] (page 4-22)
Edge direction [S7] - [D8] (page 4-21)
Edge hys. [S7] - [DA] (page 4-22)
*1: To adjust the received light amount for object detection, also change the “[S3] Response time” and
“[S7] - [D5] Emitter power” settings as necessary.
Threshold Mode ([S7] - [D2])
Selecting “Edge height” displays its parameters.
Selectable option Function description
Standard (default value) This is the standard threshold mode.
Output is generated when the received light amount exceeds the threshold.
Edge height Select Edge height when detecting with edges (differentiation operation).
Output is generated only when sudden changes in the received light amount occur.
Not used Disables the control output, preventing output regardless of the received light amount or
threshold.