Festo — EMCS-ST — 2021-03b
Operation Firmware update (file
handling)
Functions
Firmware version IODD version IODD version
v16.0.15.72_release
...
v16.0.18.92_release
V1.0.21 V1.2.6 Basic functions:
–
HMI, DIO and IO-Link
operation
–
Single point-to-
point operation
–
Point-to-point
operation with
press function
v19.0.4.107_release V1.2.6 Function extension:
–
HMI operation
–
Acknowledge
error
–
DIO operation
–
Acknowledge
error
– IO-Link operation
–
Point-to-point
operation with
intermediate posi-
tion "Pos
Imp
"
– Update firmware
– Update parameter
set
– Data backup (data
storage)
–
Save parameters
Tab. 20: Overview of firmware and IODD versions
10.2.1.1
Update the firmware (from IODD version V1.2.6)
WARNING
Risk of Injury due to Unexpected Movement of Components
For vertical or slanted mounting position: when power is off, moving parts can travel or fall uncon-
trolled into the lower end position.
• Bring moving parts of the product into a safe end position or secure them against falling.
Prerequisite for the IO-Link master/application software
– The IO-Link master must support the IO-Link standard "IO-Link BLOB Transfer & Firmware Update
V1.1", e.g. the Festo USB IO-Link Master CDSU-1 with firmware version V2.1.0.11 or higher.