1. Summary of components
1-5
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
During operation, the SPC11 ensures that the moveable mass
is moved into the saved end positions and intermediate posi-
tions at the highest possible speed with closed-loop control.
Shortly before the taught end position or intermediate posi-
tion is reached, the moveable mass is braked so that it comes
to a stand.
In order that the moveable mass remains in the taug ht end
position, it is pressed against the fixed stop with a pr essure
equal at maximum to the operating pressure.
Advantages
Compared with pneumatic-impact drives with double-sole-
noid control, this closed-loop procedure permits higher posi-
tioning speeds. Also, the following measures, which would be
required for controlling a cylinder with a double-solenoid
valve, are no longer necessary:
the use of restrictors
the use of limit switches
the use of mechanical end position cushioning
(shock absorbers)
the maintenance of fixed stops.
Compared with pneumatic-impact drives with double-sole-
noid control, the SPC11 permits:
higher machine cycle times
less vibration of the system
lower maintenance c osts.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo Soft Stop SPC11 Series and is the answer not in the manual?

Festo Soft Stop SPC11 Series Specifications

General IconGeneral
BrandFesto
ModelSoft Stop SPC11 Series
CategoryControl Unit
LanguageEnglish

Related product manuals