22
REV. 00 02/01/2015
id.:
FBC MODE FUNCTIONS
3
3.19 CALIBRATING THE TARE
It is a test that needs to be performed daily in order to
ensure the proper functioning of the weighing system.
TEST/CALIBRATION
To perform the device calibration
- Press 0
, hold it down for a few seconds then
press OK
or select TEST/CALIBRATION from the FUNCTIONS
menu.
- The “CAUTION....” message is displayed
operate as follows:
The maximum machine tilting must be <0.5° (frontal
axis) The engine speed must be 2000 rpm
TEST
1) Slowly lower the boom
2) Withdraw the bucket (A)
3) Lift the boom back up at a constant speed.
If the value displayed differs from zero (60 in this
instance), then the tare needs to be calibrated.
- Press OK
to shift to the calibration mode
TARE CALIBRATION
A