19 Mai
n
tenance
FLUXUS F808, F809
UMFLUXUS_F808_80
91V1-2-1E
N, 2019-08-2
3
1
63
Tab. 19.1
transmitter
O-ring
FLUXUS F8
08
O-ring-116x4 mm
FLUXUS F8
09, upper housing
O-ring-116x4 mm
FLUXUS F8
09, lower housing
O-ring-97x3.5 mm
162
164
Table of Contents
Table of Contents
5
Introduction
9
Regarding this User Manual
9
Safety Instructions
9
Warranty
9
Handling
10
First Inspection
10
General Precautions
10
Cleaning
10
General Principles
11
Measurement System
11
Measurement Principle
11
Measurement Arrangements
15
Description of the Transmitter
18
Fluxus F808
18
Fluxus F809
18
Keyboard
19
Selection of the Measuring Point
20
Acoustic Penetration
20
Undisturbed Flow Profile
22
Selection of the Measurement Arrangement Taking into Account the Measuring Range and the Measuring Conditions
24
Installation of FLUXUS F808
26
Location
26
Opening and Closing the Housing
26
Installation
26
Connection of the Transmitter
28
Connection of the Transducers to the Transmitter F808**-A1
29
Connection of the Transducers to the Transmitter F808**-F1
37
Connection of the Transducers to the Transmitter F808**-F2
40
Power Supply
47
Outputs
49
Serial Interface
52
Sensor Module (SENSPROM)
53
Installation of FLUXUS F809
54
Location
54
Opening and Closing the Housing
54
Installation
55
Connection of the Transmitter
57
Connection of the Transducers to the Transmitter F809**-A1
58
Connection of the Transducers to the Transmitter F809**-F1
66
Power Supply
69
Outputs
71
Serial Interface
75
Sensor Module (SENSPROM)
76
Installation of the Transducers
77
Pipe Preparation
77
Orientation of the Transducers and Transducer Distance
77
Transducer Mounting Fixture Variofix L (Permarail)
78
Transducer Mounting Fixture Variofix C
86
Transducer Mounting Fixture Permafix
93
Start-Up of the Transmitter
98
Start-Up Settings
98
Switching on
98
Initialization
99
Display
99
Hotcodes
101
Language Selection
102
Operation State Indication
102
Interruption of the Power Supply
102
Basic Measurement
103
Input of Pipe Parameters
103
Input of Fluid Parameters
104
Other Parameters
106
Selection of Channels
106
Input of the Sound Path Number
107
Transducer Distance
107
Start of Measurement
109
Detection of the Flow Direction
109
Interruption of the Measurement
109
Displaying Measured Values
110
Selection of the Physical Quantity and the Unit of Measurement
110
Toggling between Channels
110
Adjustment of the Display
111
Status Line
112
Transducer Distance
112
Advanced Measuring Functions
113
Command Execution During Measurement
113
Damping Factor
113
Totalizers
113
Settings of the Noisetrek Parallel Beam Mode
115
Settings of the Hybridtrek Mode
115
Upper Limit of the Flow Velocity
116
Cut-Off Flow
116
Uncorrected Flow Velocity
117
Measurement of Highly Dynamic Flows (Fastfood Mode)
117
Calculation Channels
118
Change of the Limit for the Inner Pipe Diameter
121
Diagnosis by Means of the Snap Function
121
Program Code
122
Data Logger and Transmission of Data
123
Data Logger
123
Transmission of Data
126
Libraries
132
Partitioning of the Coefficient Memory
132
Input of Material/Fluid Parameters Without Extended Library
133
Extended Library
134
Deleting a User Defined Material/Fluid
136
Arrangement of the Material/Fluid Scroll List
136
Settings
138
Time and Date
138
Dialogs and Menus
138
Measurement Settings
141
Contrast Settings
142
Instrument Information
142
Superuser Mode
143
Activation/Deactivation
143
Transducer Parameters
143
Defining the Flow Parameters
143
Limit of the Signal Amplification
145
Upper Limit of the Sound Speed
145
Detection of Long Measurement Failures
146
Number of Decimal Places of the Totalizers
146
Manual Reset of the Totalizers
147
Display of the Totalizer Sum
147
Display of the Last Valid Measured Value
147
Display During the Measurement
147
Outputs
148
Installation of an Output
148
Error Value Delay
151
Activation of an Analog Output
152
Configuration of a Frequency Output as a Pulse Output
153
Activation of a Binary Output as a Pulse Output
153
Activation of a Binary Output as an Alarm Output
154
Behavior of the Alarm Outputs
156
Deactivation of the Outputs
158
Troubleshooting
159
Problems with the Measurement
159
Selection of the Measuring Point
160
Maximum Acoustic Contact
160
Application Specific Problems
160
Large Deviations of the Measured Values
161
Problems with the Totalizers
161
Data Transmission
161
Maintenance
162
Cleaning
162
Examination of the O-Ring
162
A Menu Structure
164
B Units of Measurement
178
C Reference
183
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Flexim FLUXUS F808 A1 Series and is the answer not in the manual?
Ask a question
Flexim FLUXUS F808 A1 Series Specifications
General
Brand
Flexim
Model
FLUXUS F808 A1 Series
Category
Measuring Instruments
Language
English
Related product manuals
Flexim FLUXUS F808 F1 Series
186 pages
Flexim FLUXUS F809 A1 Series
186 pages
Flexim FLUXUS F801
160 pages
Flexim FLUXUS F809 F1 Series
186 pages
Flexim FLUXUS G809
181 pages
Flexim FLUXUS F501
146 pages
Flexim FLUXUS H721
229 pages
Flexim FLUXUS G608
244 pages
Flexim FLUXUS G704
257 pages
Flexim FLUXUS F60 Series
244 pages
Flexim FLUXUS ADM 7 07 Series
87 pages
Flexim FLUXUS F705**-NN Series
192 pages