FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 50 of 146
KEY
LOCK
AUTO
LOAD
:
:
:
:
Printing with key
Print interlock. Only one time printout, if
weight change is more than 10 division.
Auto print, if the gross load is bigger than
MIN WEIGHT and stable. Unload and load
the scale for next printing.
Autoprint if W>MIN WEIGHT and weight
change is more than 10d.
[
163
PRT MSG
:
NO
]
Display " PRINTING " message at printout
NO
YES
:
:
Disable
Enable
[
164
CN
:
YES
]
Ticket number on printout.
NO
YES
:
:
Disable
Enable
[
165
DATE
:
YES
]
Date printing on printout.
NO
YES
:
:
Disable
Enable
[
166
TIME
:
YES
]
Time printing on printout.
NO
YES
:
:
Disable
Enable
[
17-
LABEL SETUP
]
LABEL SETUP
Press key or key again to enter this menu.
Or press key to go to the next sub-block.
[
171
HEADER1
:
]
Header of printout, the first line.
Page 89
Maximum 20 characters.
[
172
HEADER2
:
]
Header of printout, the second line.
Page 89
Maximum 20 characters.
[
173
HEADER3
:
]
Header of printout, the third line.
Page 89
Maximum 20 characters.
[
174
FOOTER1
:
]
Footer of printout, the first line.
Page 89
Maximum 20 characters.
[
175
FOOTER2
:
]
Footer of printout, the second line.
Page 89
Maximum 20 characters.
[
176
LF BEFO
:
+2
]
Line feed before printout.
:
:
+ = Forward , - = Backward
NO,1,2….9 : Line feed quantity before data.
Example: +2 means 2 line feed forward.

Table of Contents