viii
Input Buffer Operation ....................................................................................... 6-3
Commands ......................................................................................................... 6-4
Multiple Commands ...................................................................................... 6-4
Coupled Commands ...................................................................................... 6-4
Sequential and Overlapped Commands ......................................................... 6-5
Commands Ignored When Not in Remote .................................................... 6-5
Commands that Require the Calibration Security Passcode .......................... 6-5
Long Term Commands .................................................................................. 6-5
Definition: Queries and Commands .............................................................. 6-6
Functional Elements of Commands ............................................................... 6-6
Interface Messages (IEEE-488 Only) ............................................................ 6-8
Use of *OPC?, *OPC, and *WAI.................................................................. 6-10
Local-to-Remote State Transitions .................................................................... 6-48
Check the Calibrator Status ............................................................................... 6-50
Status Byte Register ...................................................................................... 6-52
Service Request Line (SRQ) ..................................................................... 6-52
Service Request Enable Register............................................................... 6-52
Load the SRE ............................................................................................ 6-52
Event Status Register ..................................................................................... 6-53
Bit Assignments for the ESR and ESE ...................................................... 6-53
Read the ESR and ESE ............................................................................. 6-54
Load the ESE............................................................................................. 6-54
Instrument Status Register ............................................................................. 6-54
Instrument Status Change Register ................................................................ 6-54
Instrument Status Change Enable Register ................................................... 6-54
Bit Assignments for the ISR, ISCR, and ISCE ......................................... 6-54
Read the ISR, ISCR, or ISCE .................................................................... 6-55
Load the ISCE ........................................................................................... 6-55
Fault Queue ................................................................................................... 6-55
7 Operator Maintenance and Calibration ............................................. 7-1
Introduction ........................................................................................................ 7-1
Fuse Replacement .............................................................................................. 7-1
Clean the Air Filter ............................................................................................ 7-3
Clean the Exterior .............................................................................................. 7-4
User-Replaceable Parts ...................................................................................... 7-4
5730A Calibration .............................................................................................. 7-6
The Artifact Calibration Process ................................................................... 7-6
Establish Traceability .................................................................................... 7-7
Calibration Reports ........................................................................................ 7-7
Range Adjustment ......................................................................................... 7-7
DC Zeros ............................................................................................................ 7-7
Run DC Zeros ................................................................................................ 7-7
DC Zeros Reminder ....................................................................................... 7-8
Calibration ......................................................................................................... 7-8
Calibration Security Passcode ....................................................................... 7-9
Artifact Calibration ........................................................................................ 7-9
When to Adjust Calibrator Accuracy ............................................................ 7-10
Calibration Procedure .................................................................................... 7-10
Range Adjustment .............................................................................................. 7-13
Calibrate the Wideband AC Module (Option 5730A/03 or 5730A/05) ............. 7-17
Wideband Flatness Calibration Procedure ......................................................... 7-18
Calibration Check .............................................................................................. 7-20
Develop a Performance History ......................................................................... 7-21
Save Calibration Reports ................................................................................... 7-21

Table of Contents

Other manuals for Fluke 5730A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 5730A and is the answer not in the manual?

Fluke 5730A Specifications

General IconGeneral
TypeMultifunction Calibrator
Resistance Range0 to 1 GΩ
AC Voltage Frequency10 Hz to 1 MHz
DisplayColor LCD
InterfacesRS-232, Ethernet
Weight18 kg
DC Voltage Range0 to ±1100 V
Dimensions172 mm H x 432 mm W x 457 mm D (6.8 in H x 17 in W x 18 in D)