Technical Data
Measurement Specifications
11
3.3. Measurement Specifications
Measurement Specifications
Temperature Range
E1ML
E1MH
E2ML
E2MM
E2MH
E3ML
E3MH
E1RL (1C-mode)
E1RL (2C-mode)
E1RH (1C / 2C-mode); ≤ 3000°C
- reduced accuracy > 3000°C
E2RL (1C / 2C-mode)
400 - 1740°C ( 752 - 3164°F) D:S = 160:1
540 - 3000°C (1004 - 5432°F) D:S = 300:1
250 - 1100°C ( 482 - 2012°F) D:S = 160:1
250 - 1400°C ( 482 - 2552°F) D:S = 160:1
450 - 2250°C ( 842 - 4082°F) D:S = 300:1
50 - 1000°C ( 122 - 1832°F) D:S = 100:1
150 - 1800°C ( 302 - 3272°F) D:S = 300:1
550 - 1800°C (1022 - 3272°F) D:S = 100:1
600 - 1800°C (1112 - 3272°F) D:S = 100:1
1000 - 3200°C (1832 - 5792°F) D:S = 150:1
Temperature Indication up to 3200°C (5792°F)
250 - 1200°C ( 482 - 2192°F) D:S = 75:1
Lens Options
F0: 190 - 300mm (7.5 - 12")
F1: 300 - 600mm (12 - 24")
F2: 600mm - infinity (24" - ∞)
Sighting Options
Visual/Laser
Visual/Camera
Visual/LED
Accuracy
E1ML ( > 450°C / 842°F)
E1ML ( < 450°C / 842°F)
E1MH ( > 650°C / 1202°F)
E1MH ( < 650°C / 1202°F)
E2ML
E2MM (> 350°C / 662°F)
E2MM (< 350°C / 662°F)
E2MH
E3ML (> 100°C / 212°F)
E3ML (< 100°C / 212°F)
E3MH (> 100°C / 212°F)
E3MH (< 100°C / 212°F)
E1RL (no attenuation)
E1RH (no attenuation)
E2RL (no attenuation)
± (0.3% Tmeas + 1°C)
± (2.0% Tmeas + 2°C)
± (0.3% Tmeas + 1°C)
± (2.0% Tmeas + 2°C)
± (0.3% Tmeas + 2°C)
± (0.3% Tmeas + 2°C)
± (1% Tmeas + 2°C)
± (0.3% Tmeas + 1°C)
± (0.3% Tmeas + 1°C)
± (1% Tmeas + 2°C)
± (0.3% Tmeas + 1°C)
± (1% Tmeas + 2°C)
± (0.5% Tmeas + 2°C)
± (0.5% Tmeas + 2°C)
± (0.5% Tmeas + 2°C)
Repeatability
E1ML ( > 450°C / 842°F)
E1ML ( < 450°C / 842°F)
E1MH ( > 650°C / 1202°F)
E1MH ( < 650°C / 1202°F)
E2ML
E2MM
E2MH
E3ML (> 100°C / 212°F)
E3ML (< 100°C / 212°F)
E3MH (> 100°C / 212°F)
E3MH (< 100°C / 212°F)
E1RL (Tmeas in °C, no attenuation)
E1RH(Tmeas in °C, no attenuation)
E2RL (Tmeas in °C, no attenuation)
± (0.1% Tmeas + 1°C)
± (1.0% Tmeas + 1°C)
± (0.1% Tmeas + 1°C)
± (1.0% Tmeas + 1°C)
± (0.1% Tmeas + 1°C)
± (0.1% Tmeas + 1°C)
± (0.1% Tmeas + 1°C)
± (0.1% Tmeas + 1°C)
± (1% Tmeas + 1°C)
± (0.1% Tmeas + 1°C)
± (1% Tmeas + 1°C)
± (0.3% Tmeas + 1°C)
± (0.3% Tmeas + 1°C)
± (0.3% Tmeas + 1°C)
Temperature Resolution
Integrated Temperature Display
Current Loop (Analog I/O)
Network / RS485 interface
±1°C (±2°F)
±0.1°C (±0.2°F)
±0.1°C (±0.2°F)
Temperature Coefficient
0.03% full scale change per 1°C change in
ambient temperature