9.1.2. Low Temp. Multi-conductor Cable (E-2CLTCBxx)
Use the Low Temp. 12-wire multi conductor cable (E-2CLTCBxx) for wiring the Endurance
sensor with the 24 VDC power supply, all inputs, outputs, and the RS485 interface. It is a
shielded 12-conductor cable, made of 2 twisted pairs plus 8 separate wires, equipped with a
M16 DIN connector on one side and wire sleeves at the counter side. The cable is PUR
(Polyurethane) coated and withstands ambient temperatures from -40 to 105°C (-40°F to
221°F). PUR coated cables are flexible and have well to excellent resistance to against oil,
bases, and acids.
Purchasable Low Temp. 12-wire multi-conductor cables lengths are 4 m (13 ft.), 8 m (26 ft.),
15m (50 ft.), 30 m (100 ft.), 60 m (200 ft.), see Table 5.
• Temperature: -40 to 105°C (-40°F to 221°F)
• Cable material PUR- 11Y (Polyurethane), Halogen free, Silicone free
• Cable diameter: 7.2 mm (0.283 in) nominal
• Conductors:
Power supply 2 wires (black/red)
Conductor: 0.2 mm² (AWG 24), stranded tinned copper
Isolation: PE- 2YI1
Shield: none
RS485 interface 2 twisted pairs (black/white and purple/gray)
Conductor: 0,2 mm² (AWG 24), stranded tinned copper
Isolation: PE- 2YI1
Shield: CDV-15, 85% covered
Outputs and Ground 6 wires (green/brown/blue/orange/yellow/clear)
Conductor: 0,2 mm² (AWG 24), stranded tinned copper
Isolation: PE- 2YI1
Shield: none
If you purchase your own High Temp. Multi-conductor cable, use wire with
the same specifications as herein mentioned. Maximum RS485 cable length
is 1.200 m (4000 ft). Power supply (24 VDC) feed in distance to the Endurance
sensor should not extend the 60 m (200 ft.) limit.