102 Faults and warnings
9.2.8 Fill up the MP container
If the automatic feeder is equipped with a powder sensor, this will output a warning if the MP in
the container is lower than the sensor. If the sensor reports container empty for 10 portions in
succession, Warning, top up MP will appear in the display.
You rectify the warning as follows:
1. Confirm the MP warning by choosing .
2. Fill the powder container with milk powder
9.2.9 Calibration scales
If the calibration scales are not working, the calibration scales warning will appear in your dis-
play.
NOTICE!
There is a risk of malnutrition caused by incorrectly dispensed feed portions.
Malnutrition can cause impaired growth and development, increased susceptibility to illness or
even death of the calves.
► You must ensure that the end user provides his/her calves with feed using an alternative
method as long as the calibration scales are not working.
DANGER!
Fatal electric shock.
The electrical components of the automatic feeder are live.
► Always switch off the automatic feeder firstly with the Main switch and then disconnect the
power plug before working on components of the feeder.
You rectify the warning as follows:
1. Check that the circuit board for the mixer scales is correctly plugged into the main board of
the feeder.
2. Check the load rod and the calibration unit of the mixer scales.
Note: The warning is automatically deleted when the fault has been rectified.
9.2.10 ID chip
The automatic feeder is equipped with an electronic name plate (ID chip) upon which the device
number and other important information for the operation of the automatic feeder is stored.
If the ID chip is defective, the warning ID chip still xx day will appears in your display. After 30
days, the functionality of the feeder will be limited.