Faults and warnings 111
9.5.4 Calibration scales
In this menu, you check the calibration scales.
Check the calibration scales as follows:
1. Navigate via > Diagnostics to switch to the Calibration scales sub-menu.
2. Confirm check? by choosing , to check the calibration scales.
3. Confirm adjust? by choosing , to tare the calibration scales.
9.5.5 Checking stations
In this menu, you check the feeding box(es).
You check that the identification system of the feeding box is working.
You can open the feeding box valve.
In the display, you can view the control unit assigned to the feeding box.
You check the identification system of a feeding box as follows:
1. Navigate via > Diagnostics > Boxes > Feed to the Feeding box 1 or Feeding box 2
sub-menu.
2. To check the identification (antenna test), hold a transmitter near the antenna.
3. In No. ‡, you check the transmitter number.
If the transmitter number is not recognized, proceed as follows:
1. Check in the setup whether the correct identification system is configured.
2. Check that the data lines between antenna and automatic feeder are undamaged.
3. Check the setup for the allocation of the station that is causing identification problems.
You check the feeding box valve as follows:
1. Navigate via > Diagnostics > Boxes to the Feeds sub-menu.
2. Confirm open? for the valve concerned by choosing .
3. Check that the valve opens.
9.5.6 Monitoring
In this menu, you check the following faults:
How often the automatic feeder was without power (power failures).
Note: Switching on and off are also considered to be power failures.
•In Watchdog, the software is monitored.
How often the feeder control unit had to be restarted after a program error (Reset).
How often the connection to the terminal was faulty.
How often an error occurred in connection with the database.