94 Faults and warnings
You can correct the fault as follows:
1. Switch the automatic feeder off using the Main switch and disconnect the mains plug.
2. Check all components carrying feed from the mixer to the mixer drain valve or from the mixer
up to the teat for clogs and remove them.
3. Insert the mains plug again and switch the automatic feeder on using the Main switch .
4. Confirm Fault, draining the mixer by choosing .
5. Check the feed pump:
5.1. Confirm Feeding pump: start? by choosing .
6. Check the mixer drain valve:
6.1. Confirm Mixer drain: open? by choosing .
7. Check the rod electrode:
7.1. Confirm Bo. water start? by choosing , to fill the mixer with water. Check in the
Diagnostics > Sensors menu (see 9.5.3 "Checking sensors" - 110), whether the
message empty or covered appears.
7.2. Confirm in Mixer draining?, by choosing .
8. Confirm Delete fault? by choosing when you have fixed the fault.
9. Remove cleaning agent remnants from components carrying feed by rinsing them with wa-
ter.
NOTICE!
Cleaning agent remnants that enter the feed can be hazardous to the health of calves.
Remove cleaning agent remnants before recommissioning the automatic feeder.
10. Return to automatic mode.
9.1.8 Heating system
Fault, heating will be shown in the display if the heater is faulty.
Feeder operation will be interrupted. Make sure that the end user provides the calves with feed
using an alternative method as long as feed operation is interrupted.
DANGER!
Fatal electric shock.
The electrical components of the automatic feeder are live.
Always switch off the automatic feeder firstly with the Main switch and then disconnect the
power plug before working on components of the feeder.