EasyManua.ls Logo

Förster-Technik TAP5-VS2-50 - Calibrating With Scales

Default Icon
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
72 Calibration
2.8. Tilt the mixer so that the water flows into the graduated cylinder. Measure the collect-
ed water in milliliters.
2.9. In the Actual menu, enter this measured quantity using the number keys.
2.10. Confirm with .
2.11. Date now shows the current date.
2.12. Repeat the calibration to check your results.
3. Calibrate other liquid components using the same method.
Proceed as follows to calibrate powder components without calibration scales:
1. Navigate via > Calibration to the Components sub-menu.
2. In the MP menu, you calibrate the milk substitute.
2.1. Confirm MP by choosing .
2.2. Set quantity shows the amount of milk substitute (MP) to be dispensed by the auto-
matic feeder.
2.3. Runtime shows the time in which the automatic feeder should dispense the MP.
2.4. Date shows when MP was last calibrated.
2.5. Tilt the empty mixer forward.
2.6. Hold the container for the MP under the powder discharge.
2.7. Confirm Start? by choosing .
2.8. Confirm Exit automatic mode? by choosing . This message will only be dis-
played if your automatic feeder is still in automatic mode.
Powder will be dispensed.
2.9. Place the container with the collected MP on the scales.
2.10. In the Actual menu, enter the weighed quantity using the number keys.
2.11. Confirm with .
2.12. Date now shows the current date.
2.13. Repeat the calibration to check your results.
3. Calibrate other powder components using the same method.
6.2 Calibrating with calibration scales
The automatic feeder determines the actual value using the built-in automatic calibration scales
(additional equipment).
Proceed as follows to calibrate liquid components using the calibration scales:
1. Navigate via > Calibration to the Components sub-menu.
2. In the Water menu, you calibrate water.
2.1. Confirm Water by choosing .
2.2. Set qty shows the quantity of water to be dispensed by the automatic feeder.
2.3. Runtime shows the time in which the automatic feeder should dispense the water.

Table of Contents