Faults and warnings 109
9.5.1.2 Motors
Check the motors as follows:
1. Navigate via > Diagnostics to switch to the Motors sub-menu.
2. Confirm Mixer: start? by choosing , to start the mixer.
3. Confirm Powder start? by choosing , to start the powder conveyor.
4. In the flushing agent 1 menu, press .
4.1. Confirm check? by choosing , to check the cleaning agent pump.
4.2. Confirm Flushing agent: start? by choosing , to start the cleaning agent pump.
Check that cleaning agent flows from the outlet.
5. In the start flushing agent 2? menu, press .
5.1. Confirm check? by choosing , to check the cleaning agent pump.
5.2. Confirm Flushing agent: start? by choosing , to start the cleaning agent pump.
Check that cleaning agent flows from the outlet.
WARNING!
Hazardous or irritant materials!
► Collect the cleaning agent residues and additive residues and dispose of them safely. When
doing this be sure to comply with the manufacturer's instructions and national regulations for
the use and disposal of the cleaning agent and additive being used. In addition a mixer
cleaning must then be performed.
6. Confirm Feeding pump: start? by choosing , to start the feeding pump.
9.5.2 Checking the heating
In this menu, you check the boiler heating system.
Check the boiler heating system as follows:
1. Navigate via > Diagnostics to switch to the Heating system sub-menu.
2. Confirm switch on? by choosing .
3. In the Boiler menu, you check the temperature.
4. Keep the in switch on? Depressed, the boiler will then heat up. If the temperature rises,
that means the heater is working.