Faults and warnings 99
9.2 Warnings
9.2.1 Emptying the mixer
If the mixer cannot be emptied, the message Warning, draining the mixer will appear. For ex-
ample, this can be because the drain is clogged or the feeding pump is no longer running.
DANGER!
Fatal electric shock.
The electrical components of the automatic feeder are live.
► Always switch off the automatic feeder firstly with the Main switch and then disconnect the
power plug before working on components of the feeder.
You rectify the warning as follows:
1. Check all components carrying feed from the mixer to the mixer drain valve or from the mixer
up to the teat for clogs and remove them.
NOTICE!
The hose which goes from the mixer drain valve to the drain channel must not be length-
ened.
2. Check the feeding pump.
2.1. Confirm Mixer draining warning by choosing .
2.2. Confirm Feeding pump: start? by choosing .
The feeding pump will be actuated.
3. Check the mixer drain valve.
3.1. Confirm Mixer draining warning by choosing .
3.2. Confirm Mixer drain: open? by choosing .
The mixer will be drained.
4. Check the rod electrode.
4.1. Visually check the rod electrode for deposits.
4.2. Check that the rod electrode works properly (see 9.5.3 "Checking sensors" - 110).
5. Fill and drain the mixer.
5.1. Confirm Bo. water start? by choosing .
The mixer will fill up with water.
5.2. Confirm Mixer: draining? by choosing .
The mixer will be drained.
If the fault has been fixed, acknowledge the message Delete warning? in the display with .