Setup 67
5.7 ID chip
Before delivery, the ID chip is configured with the Setup settings for the automatic feeder. These
are saved in non-editable form. This means you can restore the original settings of the setup at
any time. For example, this may be necessary if you have accidentally changed a setting or the
processor board has to be replaced.
You set the ID chip as follows:
1. In the setup menu, choose the ID chip option.
2. In activated, you must specify yes because the automatic feeder is equipped with an ID
chip.
3. Confirm read? by choosing , if you wish to transfer the data from the ID chip to the pro-
cessor board.
4. Confirm your entry with .
Note: Include retro-fitted items and peripherals at this point.
5.8 Calibration scales
You activate the calibration scales as follows:
1. In the setup menu, open the Calibration scales option.
2. In activated choose yes if calibration scales have been installed.
3. Confirm your entry with .
4. In adjust?, press , to adjust the calibration scales.
5. The adjustment process begins with the taring of the calibration scales. You will be informed
of this in the message calibration scales are being tared.
6. A menu appears where you need to enter the reference weight in grams that you require for
the adjustment. If necessary, adapt the respective value in this menu (default value: 500 g).
Note: A 500 g reference weight is included in the delivery.
7. Place the reference weight with the hole on the screw in the feeding box such that it is fixed
in place, and then press , to start the adjustment process.
8. After completing the adjustment process, a corresponding message about the success or
lack of success of the adjustment will be issued. At the same time, the currently determined
weight value will be shown. After removing the calibration weight, 0 grams should be shown
here.
9. Press . Date now shows the current date.