12. Test the door and repeat if needed.
Note: You can tighten the springs a maximum of 6 x ¼ turns from the point of
resistance.
Note: The closing of the door must take at least 1.5 seconds from a 70° angle.
13.4 Install the lock case
Install the lock case to the door with M5x25 screws (2 pcs).
Note: If installing the lock case used with the smart lock kit, make sure that the lock
case is the right way around (sliding snib above lock latch).