Set Discharge Flow Sensor ID Names (TFC200/300/400)
This code applies to systems with multiple foam discharge ow sensors and a summing box installed. There
are twelve (12) names along with a two digit number that can be used to identify each foam discharge ow sensor.
If no ID names are programmed for the sensors, the factory defaults are FLOW 1, FLOW 2, FLOW 3, etc.,
based on the location of each ow sensor input connection to the summing box(es)
The summing boxes are identied, when the code is selected, and shown on the control module display as
Sb #.# (#'s refer to box and input). The following example shows two summing boxes with a total of nine inputs:
First box six inputs Sb 1.1, Sb 1.2, Sb 1.3, Sb 1.4, Sb 1.5, Sb 1.6
Second box three inputs Sb 2.1, Sb 2.2, Sb 2.3.
The factory default ID name shown in the message display for the above example is FLOW 1 through
FLOW 9.
Set Flow ID Name (Code P110)
Enter password code 1221. (Refer to Enter Password for Program Access.)
1. Press the + and – buttons and scroll to code P110.
2. Press the PRESET button.
Result: The % display shows Sb 1.1, 1.1 ashes indicating summing
box 1, input 1, message display shows the ID name.
3. Press the PRESET button (or press the INC or DEC button to scroll
inputs).
Result: The message display ashes the ID name.
4. Press the + and – buttons to scroll the ID names.
5. Press the PRESET button to choose a name.
Result: The message display ashes the ID number. (See Note)
6. Set the number (press the + and – buttons to change the digit, press
the SELECT button to move the curser to the next digit).
7. Press the MENU button to return to step 3.
8. Press and hold the MENU button for ve (5) seconds to save.
MESSAGE
DISPLAY
DESCRIPTION
DIS.
##
Discharge
F DIS.
##
Front Discharge
REAR DIS
##
Rear Discharge
L/R DIS
##.
Left Rear
Discharge
R/R DIS.
##
Right Rear
Discharge
DECK GUN
##
Deck Gun
ROOF TUR
##
Roof Turret
CROSSLAY
##
Crosslay
PCON
##
Pre-Connect
L/R PCON
##
Left Rear
Pre-Connect
R/R PCON
##
Right Rear
Pre-Connect
FLOW
##
Factory default
ID name
Note: If FRC owmeters (DFA or FPA) are used to retrieve ow rate
information, only the FRC Datalink is connected to the foam system.
IMPORTANT the owmeter ID numbers must be different than the
ow sensor ID numbers used with a summing box.