Error Codes and Fault Warnings Troubleshooting Table
The table is provided to assist in tracking down system problems, it is not meant to take the place of good
troubleshooting practices.
Code Description Probable Cause
E01
Pump communications failed Datalink cable between Control Module and Foam Pump Control
E02
Over current condition sensed Foam Pump Motor; Foam Pump Control
E03
Over temperature sensed Foam Pump Motor; Foam Pump Control
E04
Over temperature shutdown Foam Pump Motor; Foam Pump Control
E05
No temperature sensor signal Foam Pump Control
E06
RPM sensor failure, circuit open Cable between RPM Sensor and Foam Pump Control; Bad RPM Sensor
E07
RPM sensor failure, circuit shorted Cable between RPM Sensor and Foam Pump Control; Bad RPM Sensor
E08
Motor not turning Supply power to motor; Foam Pump Motor; Foam Pump Control
E09
Hardware power limit, over current protection Foam Pump Control
E10
Motor does not come up to requested speed,
RPM low
Foam Pump; Foam Pump Motor; Foam Pump Control
E11
No RPM detected from the pump motor RPM Sensor; Foam Pump Motor; Foam Pump Control
E12
Auto ush communications failed; no auto
ush mode
Datalink cable between Control Module and Electric ABF Selector
Control; Control Module; Electric ABF Selector Control
E13
A valve failed to open Electric ABF Selector Control; A Foam Valve
E14
B valve failed to open Electric ABF Selector Control; B Foam Valve
E15
Flush valve failed to open Electric ABF Selector Control; Flush Valve
E16
A valve failed to close Electric ABF Selector Control; A Foam Valve
E17
B valve failed to close Electric ABF Selector Control; B Foam Valve
E18
Flush valve failed to close Electric ABF Selector Control; Flush Valve
E19
A and B valves failed to open Electric ABF Selector Control;
E20
No Motor Power Main Motor Power Lost
F03
A foam concentrate tank empty Tank Float Switch; TankVision Pro Control; TankVision Pro Pressure
Sensor
F04
B foam concentrate tank empty Tank Float Switch; TankVision Pro Control; TankVision Pro Pressure
Sensor
F05
Request exceeds foam concentrate pump
capacity
Foam % setting to high
Table 9. Error Codes and Fault Warnings Troubleshooting