31
Repeat steps 24 - 29 for the welding voltage
At the end of the current and voltage calibration, the message [Start calibra-
tion feed system 1!] is displayed
32
To calibrate the welding wire on the power source, specify the following set-
tings:
Set the toggle switch to wirefeeder.
Set the wirefeeder controller on the interior of
the device under MANUAL to 100 %.
Set the wire diameter for the welding wire used.
Depending on the measurement, set the wire
speed controller to the relevant measured value
according to the table.
33
Disconnect the +/- current cables from the calibration station on the power
source
34
Connect the welding torch and Tuchel plug to the power source
35
Remove the gas nozzle
36
Thread the wire
37
Close the clamping lever on the wirefeeder
38
Thread the wire until it protrudes approx. 200 mm from the contact tip
39
Thread the welding wire into the intake part of the sensor
40
Use clamps to secure the welding torch in the welding wire calibration system
at the contact tip
41
Click on [Start calibration wirefeeder 1!]
42
Set the respective measured value on the power source wire speed controller.
(e.g.: M1 = 1 m)
CAUTION!
Risk of injury from emerging welding wire.
As soon as the calibration process resumes, the welding wirefeed starts and the
welding wire emerges.
Keep the welding wire calibration system away from the head and body and
wear suitable protective goggles.
Make sure that when the welding wire emerges, it does not touch any elec-
trically conducting, earthed or live parts.
Make sure that there is sufficient space for the emerging welding wire (ap-
prox. 10 m).
Make sure that no one is endangered by the emerging welding wire.
43
Press and hold the torch trigger to start the wirefeeder
77