Final current
for setting the final current so that
a) heat build-up towards the end of welding is prevented and
b) the end crater is filled (in the case of aluminium)
Unit % (of welding current)
Setting range 0 - 200
Factory setting 50
End arc length correction
For correcting the arc length at the end of welding
Unit % (of welding voltage)
Setting range -10.0 - +10.0
Factory setting 0.0
- shorter arc length
0 neutral arc length
+ longer arc length
Final current time
for setting the length of time the final current is to be active
Unit s
Setting range off / 0.1 - 10.0
Factory setting off
SFI
to activate/deactivate the SFI function (Spatter Free Ignition)
Unit -
Setting range off / on
Factory setting off
SFI HotStart
For setting a HotStart time in conjunction with the SFI ignition
During SFI ignition, a spray arc phase occurs within the set HotStart time. This increases
the heat input irrespective of the mode, thus ensuring deeper penetration right from the
very start of welding.
Unit s
Setting range off / 0.01 - 2.00
Factory setting off
Wire withdrawal
for setting the wire withdrawal value (= composite value based on backward movement
of wire and a time).
The wire withdrawal depends on the features of the welding torch.
Unit -
Setting range 0.0 - 10.0
Factory setting 0.0