212
TPS 400i LSC
ADV /600V/nc
Mains voltage (U
1
) 3 x 575 V
Max. effective primary current (I
1eff
) 14.3 A
Max. primary current (I
1max
) 22.6 A
Mains fuse protection 35 A slow-blow
Mains voltage tolerance +/-10%
Mains frequency 50/60 Hz
Cos phi (1) 0.99
Recommended earth-leakage circuit breaker Type B
Welding current range (I
2
)
MIG/MAG 3 - 400 A
TIG 3 - 400 A
Rod electrode 10 - 400 A
Welding current at 10 min/40 °C (104 °F) 40% 60% 100%
400 A 360 A 320 A
Output voltage range according to standard characteristic (U
2
)
MIG/MAG 14.2 - 34.0 V
TIG 10.1 - 26.0 V
Rod electrode 20.4 - 36.0 V
Open circuit voltage (U
0
peak / U
0
r.m.s) 70 V
Degree of protection IP 23
Type of cooling AF
Overvoltage category III
Pollution level according to IEC60664 3
Safety symbols S, CSA
Dimensions (l x w x h) 706 x 300 x 720 mm
27.8 x 11.8 x 28.4 in.
Weight 50.2 kg
110.7 lb.
Max. noise emission (LWA) 77 dB (A)

Table of Contents