EasyManua.ls Logo

Fronius TPS 600i - Process Parameters, General; Process Parameters for Start of Welding;End of Welding

Fronius TPS 600i
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100
Process parameters, General
Process parame-
ters for start of
welding/end of
welding
The following process parameters can be set and displayed for the start and end of weld-
ing:
Starting current
for setting the starting current for MIG/MAG welding (e.g. aluminium welding start-up)
Unit % (of welding current)
Setting range 0 - 200
Factory setting 135
Start arc length correction
For correcting the arc length at the start of welding
Unit % (of welding voltage)
Setting range -10.0 - +10.0
Factory setting 0.0
- shorter arc length
0 neutral arc length
+ longer arc length
Starting current time
for setting the length of time the starting current is to be active
Unit s
Setting range off / 0.1 - 10.0
Factory setting off
Slope 1
for setting the time during which the starting current is decreased or increased to the
welding current
Unit s
Setting range 0.0 - 9.9
Factory setting 1.0
Slope 2
for setting the time during which the welding current is decreased or increased to the final
current.
Unit s
Setting range 0.0 - 9.9
Factory setting 1.0