60
Correct arrange-
ment of the inter-
connecting
hosepack
Correct arrangement of the interconnecting hosepack
IMPORTANT:
- The duty cycle value (D.C.) for the interconnecting hosepack can only be attained
when the interconnecting hosepacks are laid correctly.
- Carry out R/L calibration if the arrangement of an interconnecting hosepack changes
(see page 107).
- Magnetically compensated interconnecting hosepacks make it possible to change the
arrangement without affecting the welding circuit inductivity.
Magnetically compensated interconnecting hosepacks are available from Fronius with
a minimum length of 10 m.
CAUTION! Risk of damage to components due to overheating posed by laying
the interconnecting hosepack incorrectly.
- Lay the interconnecting hosepack without loops
- Do not put anything on top of the interconnecting hosepack
- Do not wind up the interconnecting hosepack next to gas cylinders and do
not wind it around gas cylinders