EasyManua.ls Logo

Fronius TPS 600i - Welding Parameters for Manual Metal Arc Welding

Fronius TPS 600i
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
98
Press the adjusting dial to change the welding parameter
The value of the welding parameter is displayed as a horizontal scale:
The value of the selected parameter can now be changed.
Turn the adjusting dial and change the parameter
Adjust the process parameters accordingly to make user- or application-specific set-
tings on the welding system
Start welding
Welding parame-
ters for manual
metal arc welding
The following welding parameters for MMA welding can be set and displayed by pressing
the "Welding" button:
8
9
9
10
11
Main current
Unit A
Setting range depends on the power source available
Before the start of welding, the device automatically displays a standard value based on
the programmed parameters. During welding, the actual value is displayed.
Starting current
for setting a starting current value in the range 0 - 200% of the set welding current in order
to avoid slag inclusions or incomplete fusion.
The starting current depends on the electrode type.
Unit %
Setting range 0 - 200
Factory setting 150
The starting current is active for the starting current time set under the process parame-
ters.
Dynamic
to influence the short-circuiting dynamic at the instant of droplet transfer
Unit -
Setting range 0 - 100
Factory setting 20
0 Soft, low-spatter arc
100 Harder, more stable arc