118
System calibra-
tion
If two motors are used in a welding system, they need to be calibrated to maintain process
stability.
System calibration must be carried out on welding systems with PushPull units or unreeling
wirefeeders following successful installation or replacement of a wirefeeder.
A notification will be displayed.
Select "OK" and start system calibration
The system calibration wizard starts.
Follow the instructions shown
System calibration can also be started manually here.
Perform system calibration:
Select "Process parameters"
Select "Components & Monitoring"
An overview of the process parameters for components and monitoring is displayed:
How it works:
Once the torch trigger is pressed, gas pre-flow begins immediately. Wirefeeding then be-
gins, followed by ignition. If no current starts flowing before the specified length of wire
has been fed, the power source cuts out automatically.
To try again, press the torch trigger again.
1
2
2
1
1
2