TPS 500i /nc
1) Interface to a 230/400 V, 50 Hz public grid
2) A Class A equipment is not intended for use in residential locations where the elec-
trical power is provided by the public low-voltage supply system.
There can be potential difficulties in ensuring electromagnetic compatibility in those
locations, due to conducted as well as radiated radio-frequency disturbances.
Mains voltage (U
1
) 3 x 380 V 400 V 460 V
Max. effective primary current (I
1eff
) 24.5 A 23.7 A 21.9 A
Max. primary current (I
1max
) 38.8 A 37.5 A 34.7 A
Mains fuse protection 35 A slow-blow
Mains voltage tolerance -10/+15%
Mains frequency 50/60 Hz
Cos phi (1) 0.99
Max. permitted mains impedance Z
max
on PCC
1)
49 mOhm
Recommended earth-leakage circuit breaker Type B
Welding current range (I
2
)
MIG/MAG 3 - 500 A
TIG 3 - 500 A
Rod electrode 10 - 500 A
Welding current at 10 min/40 °C (104 °F) 40% 60% 100%
U
1
= 380 - 460 V 500 A 430 A 360 A
Output voltage range according to standard characteristic (U
2
)
MIG/MAG 14.2 - 39.0 V
TIG 10.1 - 30.0 V
Rod electrode 20.4 - 40.0 V
Open circuit voltage (U
0
peak / U
0
r.m.s) 82 V
Degree of protection IP 23
Type of cooling AF
Overvoltage category III
Pollution level according to IEC60664 3
EMC device class A
2)
Safety symbols S, CE, CSA
Dimensions (l x w x h) 706 x 300 x 510 mm
27.8 x 11.8 x 20.1 in.
Weight 36.7 kg
80.9 lb.
Max. noise emission (LWA) 74 dB (A)