38
Connections, switches and mechanical components
Safety
Front and rear
sides, TSt 2200c
(1) Welding torch connection
For connecting the welding torch
(2) (-) - current socket with bayonet
latch
Used in MIG/MAG welding for
- Connecting the grounding cable or
polarity reverser during MIG/MAG
welding (depending on the wire
electrode used)
- Connecting the electrode cable or
grounding cable during MMA wel-
ding (depending on the type of
electrode used)
- Connecting the TIG welding torch
(3) TMC connection (TIG Multi Connector)
For connecting the TIG welding torch
(4) (+) - current socket with bayonet latch
Used for
- Connecting the electrode cable or grounding cable during MMA welding (depend-
ing on the type of electrode used)
- Connecting the grounding cable during TIG welding
- Connecting the polarity reverser or grounding cable during MIG/MAG welding
(depending on the wire electrode used)
(5) Polarity reverser
For selecting the welding potential on the MIG/MAG welding torch
WARNING! Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described until you have thoroughly read and
understood the following documents:
- these operating instructions
- all the operating instructions for the system components, especially the safe-
ty rules
CO² 100%
Ar+ 15-20% CO²
Ar + 2.5%CO²
Steel
CuSi
CrNi
Self-shielded
Metal cored
Rutil FCW
0,6
.023
.030
0,8
.035
0,9
.040
1,0
.045
1,2
2T
4T
S4T
MANUAL
SYNERGIC
STICK
TIG
Ar 100%
(2)
(3)
(1)
(4)