Parameters for MIG/MAG standard manual welding
Parameters for
MIG/MAG stand-
ard manual weld-
ing
GPr Gas pre-flow time
Unit: Seconds
Setting range: 0 - 9.9
Factory setting: 0.1
GPo Gas post-flow time
Unit: Seconds
Setting range: 0 - 9.9
Factory setting: 0.5
Fdi Feeder inching speed
Unit: m/min (ipm)
Setting range: 1 - 18.5 (39.37 - 728.35)
Factory setting: 10 (393.7)
bbc Burn-back effect
Burn-back effect through wire withdrawal at the end of welding
Unit: -
Setting range: Aut (automatic), 0 - 0.3
Factory setting: 0
IGc Ignition current
Unit: Ampere
Setting range: 100 - 390
Factory setting: 300
Ito Length of wire that is fed before the safety cut-out trips
Unit: mm (in.)
Setting range: OFF, 5 - 100 (OFF, 0.2 - 3.94)
Factory setting: OFF
SPt Spot welding time
Unit: Seconds
Setting range: OFF, 0.3 - 5
Factory setting: 1
SPb Spot pause time
Unit: Seconds
Setting range: OFF, 0.3 - 10 (in 0.1 s increments)
Factory setting: OFF
Int Interval
Unit: -
Setting range: 2T (2-step), 4T (4-step)
Factory setting: 2T (2-step)
FAC Reset power source to factory settings
Press and hold one of the "Parameter selection" buttons for two seconds to restore
the factory settings
- when "PrG" appears on the digital display, the power source has been reset.
NOTE! The ignition time-out function (Ito) is a safety feature – if the power
source determines that no ignition has occurred after the preset wire length
has been fed, wirefeeding is stopped.