EasyManua.ls Logo

Fronius TransSteel 2200c - Parameters for TIG Welding

Fronius TransSteel 2200c
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
94
Parameters for TIG welding
Parameters for
TIG welding
F-P Pulse frequency
Unit: Hertz
Setting range: OFF; 1 - 990
(up to 10 Hz: in 0.1 Hz increments)
(up to 100 Hz: in 1 Hz increments)
(over 100 Hz: in 10 Hz increments)
Factory setting: OFF
tUP UpSlope
Unit: Seconds
Setting range: 0.01 - 9.9
Factory setting: 0.5
tdo DownSlope
Unit: Seconds
Setting range: 0.01 - 9.9
Factory setting: 1
I-S Starting current
Unit: % of main current
Setting range: 1 - 200
Factory setting: 35
I-2 Reduced current
Unit: % of main current
Setting range: 1 - 100
Factory setting: 50
I-E Final current
Unit: % of main current
Setting range: 1 - 100
Factory setting: 30
GPo Gas post-flow time
Unit: Seconds
Setting range: 0 - 9.9
Factory setting: 9.9
tAC Tacking
Unit: Seconds
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
FAC Reset power source to factory settings
Press and hold one of the "Parameter selection" buttons for two seconds to restore
the factory settings
- when "PrG" appears on the digital display, the power source has been reset.
2nd Second level of the Setup menu (see "Setup menu - level 2")
NOTE! If the power source is reset, the majority of the applied settings are
deleted. The following values remain:
- Welding circuit resistance and welding circuit inductivity