32
Synergic control
panel
No. Function
(1) Spot welding indicator
The spot welding indicator lights up if spot welding/stitch welding mode is select-
ed and the SPt parameter (spot welding time/stitch welding time) in the Setup
menu is not set to OFF
(2) 4-step stitch welding indicator
The 4-step stitch welding indicator lights up if
- Spot welding/stitch welding mode is selected and
- The SPb parameter (spot welding/stitch welding pause time) is set to a value
greater than 0 and
- The Int (interval) parameter is set to 4T
(3) 2-step stitch welding indicator
The 2-step stitch welding indicator lights up if
- Spot welding/stitch welding mode is selected and
- The SPb parameter (spot welding/stitch welding pause time) is set to a value
greater than 0 and
- The Int (interval) parameter is set to 2T
(4) Hold indicator
At the end of each welding operation, the actual values for welding current and
welding voltage are stored - the "HOLD" indicator lights up
(5) Intermediate arc indicator
A spatter-prone intermediate arc occurs between the dip transfer arc and the
spray arc. The intermediate arc indicator lights up to alert you to this critical range
(4)
(5)
(3)
(2)
(1)