Parameters for MIG/MAG standard synergic welding
Parameters for
MIG/MAG stand-
ard synergic
welding
GPr Gas pre-flow time
Unit: Seconds
Setting range: 0 - 9.9
Factory setting: 0.1
GPo Gas post-flow time
Unit: Seconds
Setting range: 0 - 9.9
Factory setting: 0.5
SL Slope
Unit: Seconds
Setting range: 0 - 9.9
Factory setting: 1
I-S Starting current
Unit: % of welding current
Setting range: 0 - 200
Factory setting: 100
I-E Final current
Unit: % of welding current
Setting range: 0 - 200
Factory setting: 50
t-S Starting current duration
Unit: Seconds
Setting range: 0 - 9.9
Factory setting: 0
t-E Final current duration
Unit: Seconds
Setting range: 0 - 9.9
Factory setting: 0
Fdi Feeder inching speed
Unit: m/min (ipm)
Setting range: 1 - 18.5 (39.37 - 728.35)
Factory setting: 10 (393.7)
bbc Burn-back effect
Burn-back effect through wire withdrawal at the end of welding
Unit: -
Setting range: Aut (automatic), 0 - 0.2
Factory setting: Aut
Ito Length of wire that is fed before the safety cut-out trips
Unit: mm (in.)
Setting range: OFF, 5 - 100 (OFF, 0.2 - 3.94)
Factory setting: OFF