EasyManua.ls Logo

Fronius TransTig 2200 Comfort - Page 101

Fronius TransTig 2200 Comfort
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
101
EN
The special HF ignition indicator remains lit as long as a value has been specified
for the HF ignition parameter.
If the “HF ignition” set-up parameter is set to “OFF”, no high frequency ignition takes place
at the start of welding. In this case, welding starts with touchdown ignition.
rPI ignition
Reversed polarity ignition
Unit -
Setting range ON / OFF
Factory setting OFF
IMPORTANT! The rPI ignition function
- is only available on the MagicWave power source
- is not recommended for welding light-gauge sheets
L/R alignment
L (inductivity) - welding circuit inductivity (in microhenry)
R (resistance) - welding circuit resistance (in mOhm)
See the "L/R alignment" section for further details.
Ignition time-out
Time until safety cut-out is triggered after abortive ignition attempt
Unit s
Setting range 0,1 - 9,9
Factory setting 5
IMPORTANT! "Ignition Time-Out" is a safety function so it cannot be deactivated. A de-
scription of the ignition time out function may be found in the Chapter "TIG welding".
Arc break
Arc break watchdog
Time until safety cut-out following an arc break
Unit s
Setting range 0,1 - 9,9
Factory setting 2
IMPORTANT! The arc break watchdog is a safety function and cannot be deactivated. A
description of the arc break watchdog function may be found in the section "TIG welding".

Table of Contents