122
General
Service codes
during calibration
of the push-pull
unit
No. Push-pull unit Wire feed speed
00 Fronius KD 7000
Fronius VR 1530 KD
22 m/min or 866 ipm
01 Fronius KD 7000
Fronius VR 1530 KD
30 m/min or 1181 ipm
02 Fronius Robacta KD Drive
Fronius Robacta Plasma KD Drive
Fronius Robacta Laser KD Drive
10 m/min or 394 ipm
03 Fronius Robacta KD Drive
Fronius Robacta Plasma KD Drive
Fronius Robacta Laser KD Drive
22 m/min or 866 ipm
15 Fronius KD 7000
Fronius VR 1530 KD
10 m/min or 394 ipm
18 Fronius Robacta KD Drive
Fronius Robacta Plasma KD Drive
Fronius Robacta Laser KD Drive
5 m/min or 197 ipm
19 Fronius KD 4010 10 m/min or 394 ipm
21 Binzel Torch Drive IWG 8 m/min or 315 ipm
25 Fronius KD 7000
Fronius VR 1530 KD
10 m/min or 394 ipm
The following abbreviations are used for the service codes shown during calibration of the
push-pull unit:
KD = Cold wire-feed unit
PPU = Push-pull unit
vDmin = minimum wire feed speed
vDmax = maximum wire feed speed
Service codes when the drive units are disengaged (open-circuit calibration)
Cause: Incorrect measurement during
push-pull calibration
Remedy: Repeat push-pull calibration
St1 - E1, St1 - E3
Cause: At minimum wire feed speed, the
wire-feed unit motor does not de-
liver any actual rotational speed
value.
Remedy: Repeat the push-pull calibration.
If the error message re-appears:
Contact After-Sales Service.