123
EN
St1 | E 2, St1 - E5
Cause: At maximum wire feed speed, the
wire-feed motor does not deliver
any actual rotational speed value.
Remedy: Repeat the push-pull calibration.
If the error message re-appears:
Contact After-Sales Service.
Cause: At minimum wire feed speed, the
motor of the push-pull unit does
not deliver any actual rotational
speed value.
Remedy: Repeat the push-pull calibration.
If the error message re-appears:
Contact After-Sales Service.
Cause: At maximum wire feed speed, the
motor of the push-pull unit does
not deliver any actual rotational
speed value.
Remedy: Repeat the push-pull calibration.
If the error message re-appears:
Contact After-Sales Service.
Cause: Push-pull calibration was inter-
rupted: Quick-stop was activated
by pressing the torch trigger.
Remedy: Repeat push-pull calibration
Service codes when the drive units are engaged (engaged calibration)
Cause: "Push-pull calibration - open-cir-
cuit" has not been carried out
Remedy: Carry out "push-pull calibration -
open-circuit"
Cause: At minimum wire feed speed, the
wire-feed unit motor does not de-
liver any actual rotational speed
value.
Remedy: Repeat the push-pull calibration.
If the error message re-appears:
Contact After-Sales Service.
Cause: At minimum wire feed speed, the
motor of the push-pull unit does
not deliver any actual rotational
speed value.
Remedy: Repeat the push-pull calibration.
If the error message re-appears:
Contact After-Sales Service.