EasyManuals Logo

Fronius TransTig 2200 Comfort User Manual

Fronius TransTig 2200 Comfort
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #179 background imageLoading...
Page #179 background image
179
EN
Service codes
displayed in con-
junction with the
digital gas control
option
Displayed Service
codes in conjunc-
tion with cold
wire-feed unit
Cause: The gas watchdog option has de-
tected that there is no gas pres-
sure
Remedy: Check protective gas shield sup-
ply, connect new gas cylinders or
gas cylinder valves/open gas
pressure regulator
The following abbreviations are used for the service codes shown in conjunction with cold
wire-feed units:
KD = Cold wire-feed unit
PPU = Push-pull unit
vDmin = minimum wire feed speed
vDmax = maximum wire feed speed
Cause: The external supply voltage has
dropped below the tolerance limit
Remedy: Check the external supply volt-
age
Cause: Wire-feed unit motor is sticking or
defective
Remedy: Check or replace the wire-feed
unit motor
Cause: The external supply voltage has
dropped below the tolerance limit
Remedy: Check the external supply volt-
age
Cause: No actual speed value from the
wire-feed unit motor
Remedy: Check actual value and leads, if
the error persists contact After-
Sales Service
Cause: No actual speed value from the
wire-feed unit motor
Remedy: Check actual value and leads, if
the error persists contact After-
Sales Service

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 2200 Comfort and is the answer not in the manual?

Fronius TransTig 2200 Comfort Specifications

General IconGeneral
BrandFronius
ModelTransTig 2200 Comfort
CategoryPortable Generator
LanguageEnglish

Related product manuals