193
EN
TransTig
2500 / 3000 Com-
fort MV
TT 2500 Comfort MV TT 3000 Comfort MV
Mains voltage 3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
Mains voltage tolerance ± 10 % ± 10 %
Mains frequency 50 / 60 Hz 50 / 60 Hz
Mains fuse protection (slow-blow)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
16 A
32 A
32 A
16 A
32 A
32 A
Mains connection
1)
Z
max
at PCC
3)
= 172 mOhm
Z
max
at PCC
3)
= 97 mOhm
Primary continuous power (100% d.c.
2)
)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
4,7 kVA
4,1 kVA
4,3 kVA
5,9 kVA
5,0 kVA
4,3 kVA
Cos phi 0,99 0,99
Welding current range (3-phase)
TIG 3 - 250 A 3 - 300 A
Electrode 10 - 250 A 10 - 300 A
Welding current range (single phase)
TIG 3 - 220 A 3 - 220 A
Electrode 10 - 180 A 10 - 180 A
Welding current at 3 x 400 - 460 V
10 min/40 °C (104 °F) 45% d.c.
2)
- 300 A
10 min/40°C (104°F) 50% d.c.
2)
250 A -
10 min/40°C (104°F) 100% d.c.
2)
200 A 240 A
Welding current at 3 x 200 - 240 V
10 min/40°C (104°F) 35% d.c.
2)
- 300 A
10 min/40°C (104°F) 40% d.c.
2)
250 A -
10 min/40°C (104°F) 100% d.c.
2)
180 A 210 A
Welding current at 1 x 200 - 240 V
10 min/40°C (104°F) 50% d.c.
2)
220 A -
10 min/40°C (104°F) 55% d.c.
2)
- 220 A
10 min/40°C (104°F) 100% d.c.
2)
190 A 190 A
Open circuit voltage 85 V 85 V
Working voltage
TIG 10,1 - 20,0 V 10,1 - 22,0 V
Electrode 20,4 - 30,0 V 20,4 - 32,0 V
Striking voltage (U
p
) 10 kV 10 kV
The arc striking voltage is suitable for manual operation
Degree of protection IP 23 IP 23
Type of cooling AF AF
Insulation class B B
EMC emission class
(in accordance with EN/IEC 60974-10)
AA