EN
dt1
delay time 1 - time by which the start of wirefeeding is delayed after the beginning of main
current phase I
1
(only where an optional cold wire-feed unit is connected)
Unit s
Setting range OFF / 0.1 - 9.9
Factory setting OFF
dt2
delay time 2 - time by which the start of wirefeeding is delayed after the beginning of main
current phase I
1
(only where an optional cold wire-feed unit is connected)
Unit s
Setting range OFF / 0.1 - 9.9
Factory setting OFF
Fdb
Feeder backward - wire withdrawal (cold wire-feed unit option)
Unit mm in.
Setting range OFF / 1 - 50 OFF / 0.04 - 1.97
Factory setting OFF OFF
IMPORTANT!Wire withdrawal prevents the welding wire from burning at the end. Before
the welding current is switched off, the wire is withdrawn to the set value. A prerequisite
for this function is that the arc has ignited.
FAC
Factory - for resetting the welding machine
Press and hold the Store button for 2 s to reset the machine to the factory settings. When
the digital display shows "PrG", the welding system has been reset.
IMPORTANT! When the welding system is reset, all the personal settings in the set-up
menu are lost. Jobs are not deleted when the welding machine is reset - these are pre-
served. Welding parameter settings in set-up menu - level 2 are not deleted.
2nd
set-up menu - level 2: second level of the set-up menu

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 800 Job and is the answer not in the manual?

Fronius TransTig 800 Job Specifications

General IconGeneral
BrandFronius
ModelTransTig 800 Job
CategoryPortable Generator
LanguageEnglish

Related product manuals