CAUTION!
An inadequately dimensioned electrical installation can cause serious damage.
The mains lead and its fuse must be dimensioned to suit the local power supply. The
technical data shown on the rating plate applies.
Generator-pow-
ered operation
(MW 1700 / 2200,
TT 800 / 2200)
The MW 1700 / 2200 and TT 800 / 2200 power sources are generator-compatible, provid-
ed that the maximum apparent power delivered by the generator is at least 10 kVA.
IMPORTANT! The voltage delivered by the generator must never exceed the upper or low-
er limits of the mains voltage tolerance range. Details of the mains voltage tolerance can
be found in the "Technical data" section.