64
Special 4-step
mode:
variant 3
Variant 3 of special 4-step mode is activated when the special 4-step mode (SFS) set-up
parameter -is set to "3".
In variant 3, push forward and hold the torch trigger to start intermediate lowering. Release
the torch trigger to resume the main current I
1
.
When the torch trigger is pulled back, welding ends immediately without downslope and
final current.
Special 4-step mode: Variant 3
Special 4-step
mode:
variant 4
Variant 4 of the special 4-step mode is activated when the SFS set-up parameter is set to
"4".
- Welding start-up and welding: briefly pull back and release the torch trigger - the weld-
ing current will rise at the specified upslope value from the starting current I
S
until it
reaches the main current value I
1
.
- Push forward and hold the torch trigger for intermediate lowering
- Release the torch trigger to resume the main current I
1
- End of welding: briefly pull back and release the torch trigger
Special 4-step mode: variant 4
I
t
I
1
GPr
I
S
G-L / G-H
I
1
I
2
t
up
I
t
I
1
GPr
I
S
t
down
I
E
G-L
G-H
I
1
I
2
t
up
t
E
t
S

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 800 Job and is the answer not in the manual?

Fronius TransTig 800 Job Specifications

General IconGeneral
BrandFronius
ModelTransTig 800 Job
CategoryPortable Generator
LanguageEnglish

Related product manuals