138
TransTig
2500 / 3000 Job
Striking voltage (U
p
) 9.0 kV 9.5 kV
The arc striking voltage is suitable for manual operation.
Degree of protection IP 23 IP 23
Type of cooling AF AF
Insulation class B B
EMC emission class
(in accordance with EN/IEC 60974-10)
A A
Dimensions L x W x H (with handle) 485 / 180 / 344 mm
19.1 / 7.1 / 13.5 in.
485 / 180 / 390 mm
19.1 / 7.1 / 15.4 in.
Weight (without handle) 14.2 kg
31.3 lb.
16.4 kg
37 lb.
Weight (with handle) -
-
16.8 kg
37 lb.
Mark of conformity S, CE S, CE
TT 800 Job TT 2200 Job
TT 2500 Job TT 3000 Job
Mains voltage 3 x 400 V 3 x 400 V
Mains voltage tolerance ± 15 % ± 15 %
Mains frequency 50/60 Hz 50/60 Hz
Mains fuse protection (slow-blow) 16 A 16 A
Mains connection
1)
Z
max
at PCC
3)
= 172 mOhm
Z
max
at PCC
3)
= 97 mOhm
Primary continuous power (100% d.c.
2)
) 5.1 kVA 5.7 kVA
Cos phi 0,99 0,99
Welding current range
TIG 3 - 250 A 3 - 300 A
Electrode 10 - 250 A 10 - 300 A
Welding current at
10 min/40 °C (104 °F) 45% d.c.
2)
- 300 A
10 min/40 °C (104 °F) 50% d.c.
2)
250 A -
10 min/40 °C (104 °F) 60% d.c.
2)
240 A 270 A
10 min/40 °C (104 °F) 100% d.c.
2)
210 A 230 A
Open circuit voltage 85 V 85 V
Working voltage
TIG 10.1 - 20.0 V 10.1 - 22.0 V
Electrode 20.4 - 30.0 V 20.1 - 32.0 V
Striking voltage (U
p
) 10 kV 10 kV
The arc striking voltage is suitable for manual operation.
Degree of protection IP 23 IP 23
Type of cooling AF AF
Insulation class B B
EMC emission class
(in accordance with EN/IEC 60974-10)
A A
Dimensions L x W x H (with handle) 560 / 250 / 435 mm
22.0 / 9.8 / 17.1 in.
560 / 250 / 435 mm
22.0 / 9.8 / 17.1 in.

Table of Contents